Abstract:Double-ring gear reducer with Central inputting shaft is studied. The basic structure of reducer as well as testing equipment, probe spot and testing method of Structure-borne noise and air-borne noise is presented. Based on frequency spectrum of each point, amplitude spectrum of structure-borne noise and testing results of air-borne noise, the authors analyze the vibration characters and latent faults of double-ring gear reducer, coming to the value and the cause of the noise, providing theoretical basis for proper design of the double-ring gear reducer and method of reducing its vibration and noise.