A dynamic control arithmetic and mathematic model of secondary cooling system for ROKOP billet concasting has been developed in view of the changes of casting speed during concasting process and the high fluctuation of surface temperature due to the use of static control method. By means of computer simulation and by comparison between static and dynamic control method, it proves that the latter one is more adaptive to the changes of casting speed, which leads to lower fluctuation of surface temperature.