Abstract:Based on the domestic experimental data of multi-storey concrete frame structures, the relationship between curvature ductility of concrete frame column and structural displacement ductility is proposed. 32 sets experimental data of system displacement ductility and the corresponding storey displacement ductility, which are mainly obtained from beam hinge yield mechanism and failure mechanism, are collected, and statistical property of system placement ductility is analyzed. Curvature ductility of concrete frame column is derived from storey displacement ductility factor by the classical analytic solution, and relationship between curvature ductility of frame column and structural displacement ductility is established. Correlation coefficient (R) for fitting power exponent function model and sample test data is 0.775. Results of nonlinear numerical analysis examples show that statistical function model is able to direct the ductility control design of concrete frame column.