  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    基于相似性原理建立覆冰分裂导线脱冰动力响应缩比模型,首次实现了分裂导线子导线覆冰和脱冰缩比模拟试验方法。搭建了双分裂导线脱冰缩比模拟试验平台,可测量导线脱冰后的面内、面外和扭转运动,导线张力和挂点支反力纵向、竖向和水平分量时程。对典型双分裂导线子导线部分脱冰、子导线拉链式脱冰和两根子导线异步脱冰等情况进行了缩比模拟试验,测量得到了导线冰跳高度、横向摆幅、扭转角、导线张力以及导线挂点支反力随时间的变化。

    Abstract:

    Based on similarity principles, this study proposes a reduced-scale modeling and testing method to investigate the dynamic responses of twin-bundle conductor lines after ice-shedding. The processes of ice-accretion and subsequent shedding on sub-conductors of bundled conductors were successfully simulated. A reduced-scale experimental platform was established to measure the in-plane, out-of-plane, and torsional motions of conductors after ice-shedding, as well as the time histories of conductor tension and the longitudinal, vertical, and horizontal components of reaction forces at the suspension points. Reduced-scale tests were conducted on a representative twin-bundle conductor line under three conditions: partial ice-shedding and unzipping ice-shedding from a single sub-conductor, and asynchronous ice-shedding between two sub-conductors. The variations in jumping height, lateral swing amplitude, torsion angle, and conductor tension, along with the reaction forces at suspension points over time, were recorded and analyzed.